SL-2000B Instruction Manual 04.26.12 21
DIP Switches
The Control Board DIP switches must be set to accommodate your particular type of installation. Since the
SNGL / DUAL, SEQ1, and SEQ2 DIP switches are used by dual gate operator systems, they will be discussed
in the following steps.
Step 4
Make sure the control box power switch is OFF.
Step 5
Unscrew and remove the control box cover. Use a small
screwdriver to move the SNGL / DUAL DIP switch to DUAL
(see illustration)
.
CONTROL BOARD SETTINGS FOR DUAL INSTALL
SEQ1
SEQ2
ON OFF
Open & Close Simultaneously
ALWAYS USE THIS FOR SLIDE GATE
OFF ON
N/A
NOT APPLICABLE
ON ON
N/A
NOT APPLICABLE
OFF OFF
N/A
NOT APPLICABLE
1234
ON
OBSTRUCT
SENS.
PULL/PUSH
SEQ1
SNGL/DUAL
SEQ2
MIN MAX
LEARN
VOLTAGE READINGS
18VacTransformer 18.0to22.0Vac
10WSolarpanel(single) 18.0to22.0Vdc
In FULL SUN — measure voltage with the Solar Panel Disconnected.
12V,7amphourBattery 12.5to13.5Vdc
Measure voltage at battery terminals with battery disconnected
Chargingcircuit 12.0to14.8Vdc
Measure voltage at battery terminals with battery connected